Roofs, ceilings (top floor attic), thermal bridges
Dimensions
2000x600 mm
Thickness
30 - 40 - 50 - 75 - 100 - 125 - 150 - 175 mm
Compressive stress at 10%
deformation σ10
≥50 kPa
Reaction to fire
Euroclass E
Water vapour transmission μ
5 (wood wool)
20/40 (EPS)
Declared thermal conductivity λD
0.071 W/mK (wood wool)
0.038 W/mK (EPS)
Declared thermal resistance RD
0.65 m2K/W (30 mm)
0.90 m2K/W (40 mm)
1.15 m2K/W (50 mm)
1.85 m2K/W (75 mm)
2.50 m2K/W (100 mm)
3.15 m2K/W (125 mm)
3.80 m2K/W (150 mm)
4.45 m2K/W (175 mm)